Summary
A solar project developer engaged CEA to investigate widespread glass breakage across multiple PV sites. CEA conducted comprehensive on-site inspections and structural assessments, which pointed to possible issues related to module durability and mounting system compatibility.
Examples of glass breakage
Case Study: Identifying and Validating Root Causes of Glass Breakage in PV Modules
To validate these concerns, Intertek CEA proposed laboratory testing that closely replicated actual field mounting conditions. Using the original purlins and clamps, Intertek CEA performed static load tests in accordance with IEC 61215-2 protocols. This setup allowed for a more accurate simulation of real-world torsional and bending stresses than conventional rigid lab fixtures.
“Intertek CEA’s investigation identified the likely root causes of breakage and provided the client with actionable evidence to hold responsible parties accountable.”
Results
Field Investigation Findings:
Over 2,600 modules across multiple sites were found with glass breakage.
Breakage rates varied between the two module manufacturers.
While some failures were clearly linked to impact damage, structural concerns with the mounting system remained a leading suspect.
It was identified that mounting instructions required additional “bumpers” on some modules which were not present during the filed inspection.
Laboratory Testing Findings:
Static and dynamic mechanical load tests revealed weaknesses in the underlying racking design, which allowed excessive torsion on the modules.
Some modules failed due to electrical continuity loss or internal cell cracking under stress.
Although the glass did not break during testing, significant twisting and torsion were observed factors that, when combined with other field stressors, are likely contributors to glass breakage.
Glass surface tension was measured, and inherent stresses in some modules were identified.
Conclusion
Intertek CEA’s investigation identified the likely root causes of breakage and provided the client with actionable evidence to hold responsible parties accountable. A critical insight from this case was the value of replicating real-world conditions in laboratory testing. Unlike standard certification tests, which use rigid fixtures and uniform stress application, Intertek CEA’s approach mirrored the actual flexibility and torsion seen in field-mounted systems. This method uncovered failure modes that would likely remain hidden in conventional tests.
While dynamic mechanical load testing is typically part of Intertek CEA’s protocol, it was not applied in this project. However, it remains a valuable method for further assessing long-term risk—especially when using original mounting components to simulate true field behavior. Accurately replicating site conditions in testing is essential for understanding operational risk and improving system design.
Junction box failures are rising across utility-scale solar. Intertek CEA experts reveal common defects, inspection gaps, and how to prevent safety, production, and warranty risks.
In this article, Joerg Althaus of Intertek CEA explains why lost bypass diodes in PV modules are a hidden fire risk: they can pass standard factory and field inspections, yet create severe overheating when shading occurs.
In this pv magazine webinar, experts from Intertek CEA and AePVI explore how developers, EPCS and investors can implement a testing and inspection program that is tailored to the specific needs of their PV plant.
pv magazine: Jörg Althaus and Huatian Xu detail how the Middle East’s rapid solar expansion is shaped by both aggressive local-content industrial policies and the region’s uniquely harsh desert conditions.
PV Tech: Joerg Althaus, Intertek CEA’s Director of Engineering Services and Quality Assurance, warns that racking complexity, corrosion, evolving supply chains, and rising glass breakage risks pose growing challenges to solar PV projects.
pv magazine: Jörg Althaus of Intertek CEA and Andreas Fladung of Aerial PV Inspection highlight how electroluminescence (EL) testing — including drone-based approaches — can uncover microcracks, early degradation, and installation-related damage.
pv magazine: Intertek CEA's engineering experts highlight how overlooked site-specific challenges such as poor soil conditions, flash floods, complex terrain, and extreme wind loading in Southeast Asia can derail solar projects if not addressed early through rigorous engineering and civil due diligence.
pv magazine: Solar modules are growing larger, thinner, and more powerful—but a recurring issue is emerging worldwide: broken glass. According to Intertek CEA’s Joerg Althaus, these cracks often start near the frame or clamps and can spread from a few panels to thousands, without any obvious cause like hail or mishandling.
As solar deployments continue to grow, so do the risks of module failures, underperformance, and safety hazards—many of which are preventable with the right knowledge. In this Solar Power World webinar, Intertek CEA Senior Engineering Managers Claire Kearns-McCoy and Ankil Sanghvi explain how understanding common pitfalls—from thermal events to electrical failures—can help developers avoid millions in losses.
CEA conducted factory, pre-installation, and post-installation inspections for 1 GW solar PV portfolio in Chile. The goal was to assess module quality and identify defects from manufacturing to installation. The inspections focused on electroluminescence (EL) imaging and visual inspection to detect potential soldering issues, microcracks, and other module degradation mechanisms. A total of 8,520 images were taken.
A solar project developer engaged CEA to investigate widespread glass breakage across multiple PV sites. CEA conducted comprehensive on-site inspections and structural assessments, which pointed to possible issues related to module durability and mounting system compatibility.
This case study explores a thermal event inspection carried out by Clean Energy Associates (CEA) at a rooftop solar PV installation. CEA found the access to the roof was unsecured that allowed unauthorized cleaning of the site prior to the start of the investigation.
Claire Kearns-McCoy and Paul Wormser consider the lasting impact of a May 2019 hailstorm that damaged 400,000 solar panels in Texas.
In this webinar hosted by the American Solar Energy Society's PV Technical Division, CEA's Engineering Manager Claire Kearns-McCoy discusses solar PV module quality risks.
CEA’s Vice President of Marketing, Jake Edie, recently wrote an article in Renewable Energy World about the most surprising findings in clean energy and what developers and buyers will be watching most closely as 2024 unfolds.
After years of improving quality standards, solar cell cracking appears to be on the rise again, perhaps due to new manufacturers entering the sector. Clean Energy Associates’ (CEA) senior engineering manager Claire Kearns-McCoy considers ways to stop the rot.
Intertek CEA's extensive field research unveils the hidden threats in solar PV modules, emphasizing the critical role of Electroluminescence (EL) testing in detecting unseen damages. Our findings highlight the lifecycle of module defects, the surge in microcracks, and the pivotal importance of visual inspections in identifying issues often missed by other methods.
Uncover the truth about solar rooftop safety. Download Intertek CEA's report, learn common risks, and strategize remediation.
pv magazine Roundtables USA included this presentation by CEA’s Senior Project Manager/Solar Engineer, Claire Kearns-McCoy on the importance of using EL imaging to ensure PV module quality.